Chiller Solutions Fluid Solutions On-line Store Affiliates General Services Contact Legacy Chiller Systems
 
 
Knowledge Base Index
 Capacity Tables 74 Articles 
 Industry Articles 33 Articles 
 Legacy Customer Interests 6 Articles 
 Legacy E- Training 11 Articles 
 Maintenance 1 Articles 
 OEM - Service Bulletins 1 Articles 
 System Installation 4 Articles 
 Systems Design 4 Articles 
 Troubleshooting 29 Articles 
Knowledge Base Search
Keywords  
Article Type  
Top Ten Articles
Water loop piping system design
Chiller Installation, Startup, and Maintenance
Glycol - Adding to chiller loop
Chiller Systems Recommended Maintenance
Closed Loop Chiller System - Automatic Air Vents
Chiller Problems - Microprocessor Low Pressure error
Chiller System Microprocessor Programming
Chiller Problems - Microprocessor Low Flow error
Chiller Systems - Starting your Chiller
Chiller Systems - Flooded Condenser Valves
My Recently Viewed Articles
Air Conditioning and Refrigeration Systems - Hot Gas Bypass
Air Conditioning and Refrigeration Systems - Hot Gas Bypass

SUMMARY
This article provides information as to how to limit the minimum evaporating pressure in air conditioning and refrigeration systems during periods of low load.

RESOLUTION
On many air conditioning and refrigeration systems it is desirable to limit the minimum evaporating pres-sure during periods of low load either to prevent coilicing or to avoid operating the compressor at a lower suction pressure than it was designed to operate.

Various methods have been used to achieve this result— integral cylinder unloading, gas engines with vari-able speed control, or multiple smaller systems.Compressor cylinder unloading is used extensively onlarger systems but is too costly on small equipment,usually 10 hp and below.

Cycling the compressor with a low pressure cutout control is a method often used but is being re-evaluated for three reasons.

1.On-off control on air conditioning systems is uncomfortable and does a poor job of humidity and mold control.

2.Compressor cycling reduces equipment life.

3.In most cases, compressor cycling is not economicalbecause of peak load demand charges.

One method that offers a practical and economical solution to the problem, is to bypass a portion of the hot discharge gas directly into the low side. This is done by amodulating control valve — commonly called aDischarge Bypass Valve (DBV). This valve, which openson a decrease in suction pressure, can be set to auto-matically maintain a desired minimum evaporating pressure regardless of the decrease in evaporator load.

See attached PDF articles for additional information.

Posted 12/25/2005 :: 728 views
 
Related Articles
Sporlan - Using a T-P chart as a troubleshooting tool
Refrigeration Engineering Quick Reference Guide
T-P chart pocket size

Need instant sales support?

Call our TOLL FREE support line: 1-877-988-5464

OR

Live chat by BoldchatPlus
CRM by Boldcenter

Need a FAST quote??

 

CLICK HERE

To register or login to your Quote Wizard account and save up to 40%


Order your CDKEY catalog TODAY!

Featured Affiliate
UsedChillerStore.com

For both Buyers and Sellers this site offers a NO COST, Effective and Easy alternative to expensive auction sites or resellers who charge commissions. Our goal is to provide sellers an way to expose their used chiller equipment to a vast numbers of qualified buyers while giving buyers the ability to locate the equipment they need as quickly as possible.


Buy/Sell used and new overstock chillers FREE at UsedChillerstore.com

Home | Chiller Solutions | Fluid Solutions | On-line Store | Affiliates | General Support | Contact Us | Site Map | Links
Questions or problems regarding this web site should be directed to support@Legacychillers.com.
Copyright © 2007 Legacy Chiller Systems (USA). All rights reserved.
Toll free within USA/CANADA  - 877-988-5464